Product Name: Firefighter thermal protective suit
Model: FGR-F/A
Parameters:
1. General Requirements
1.1 Compliant with XF634-2015 Standard for Firefighter Thermal Protective Clothing.
2. Structure
2.1 The thermal insulation head cover features a colorless, flame-retardant face shield window. , Face shield thickness 5 ± 0.2mm。
2.2 Insulated jacket, insulated pants, insulated hood ( Includes a fire helmet ) It consists of heat-insulating gloves and heat-insulating foot covers. The upper garment features an air-breathing apparatus pouch.
3. Technical Performance
3.1 Outer fabric performance:
3.1.1 Flame-retardant performance: Afterflame duration 0S , length of damage in the latitude and longitude directions 13mm、10mm。
3.1.2 Tensile strength at break: Warp direction 2400N , zonal 1500N。
3.1.3 Tear strength: Warp direction 140N , zonal 100N。
3.1.4 Thermal stability performance: Dimensional change rate in warp and weft directions 0%、1%。
3.2 Thermal insulation fabric performance:
3.2.1 Flame-retardant performance: Afterflame duration—warp direction 1.3S , latitudinal 1.2S , length of damage in the latitude and longitude directions 42mm、45mm。
3.2.2 Thermal stability performance: Dimensional change rate in warp and weft directions 9%。
3.3 Comfort layer performance :
3.3.1 Burn time 0S, Longitudinal damage length 60mm , latitudinal damage length 52mm。
3.3.2 Tensile strength at break: Warp direction 490N , zonal 380N。
3.4 Thermal insulation hood performance:
3.4.1 High-temperature resistance: After undergoing high-temperature performance testing, there was no carbonization, melting, or dripping; the window showed no obvious deformation or damage.
3.4.2 Field of view: Left and right fields of view 105 ° , Upper field of vision 7 ° , Lower field of view 45 °。
3.5 Overall performance:
3.5.1 Thermal protection performance: TPP32 cal/c square meter
3.5.2 Seam strength 1200N
3.5.3 Radiation and thermal penetration resistance: The temperature rise on the inner surface reaches... 24 The time in ℃ 70 Second.
4. Insulated gloves
4.1 Five-finger split design with flame-retardant and non-slip layers on the palm and fingers.
4.2 Dexterity of heat-insulating gloves: The minimum test rod diameter that can be handled is – 6.5mm . Performance level is 4 Level.
Product Message
Our website uses cookies and similar technologies to personalize the advertising shown to you and to help you get the best experience on our website. For more information, see our Privacy & Cookie Policy
Links:Jiangxi Fire Association Jiangxi Fire Network Beijing Fire Network China Fire Association China Fire Online
Telephone:
0792-8798119
Fax:
0792-8798119
E-Mail::
jjhcxf@163.com
Address:
No.6, Tonggang East Road, Chengxi Port District, Economic Development Zone, Jiujiang City, Jiangxi Province
Scan code to enter mobile terminal
Scan code to add WeChat public number
SAF Coolest v1.2 设置面板 GAGSD-ZGYF-JWZDE-ZDF
无数据提示
Sorry, the current column has no content for the time being.!
You can view other columns or returnHome Page